AtticBeam
EXISTING ROOF DECKING & FINISHES
EXISTING RIDGE BEAM
EXISTING RAFTER
NEW SIMPSON H2.5A HURRICANE STRAP @ EACH RAFTER
NEW (2) 1 3 4 "x16" LVL RIDGE BEAM. MAX CLEAR SPAN IS 19'-0". (WEYERHAEUSER BRAND, MIN Fb=2,600psi, MIN E=2.0ksi OR APPROVED EQUIV. PRODUCT).
NOTES: 1. REST BEAM ENDS ON (2) JACK STUDS & (2) KING STUDS. 3" MINIMUM BEARING LENGTH. 2. WITH NEW BEAM INSTALLED EXISTING RIDGE BEAM KICKERS, AND INTERIOR WALL WITH DOOR BETWEEN FINISHED AND UNFINISHED ATTIC MAY BE REMOVED. 2" 6" 6" 2" COLLAR TIES NEW FINISHES
3 1 8 " TRUSSLOK SCREWS IN (3) ROWS @16" o/c ON EACH SIDE
ALIGN NEW BEAM WITH THE WALL CORNER FORMED BY THE STAIRWELL AND THE HALLWAY TO THE BACK DECK
DRAWN BY
RIDGE BEAM
JM
SCALE
2"=1'-0"
o f G e o r g i a Foundation Repair & Waterproofing
1366 Village Park Drive NE Brookhaven, GA 30319
DATE
12/5/2017
This drawing is the sole property of Engineered Solutions of Georgia. Reproducing or copying this drawing, in whole or in part, is prohibited without the express written permission of Engineered Solutions of Georgia. It is only to be used for the project designated herein and may not be used for any other project. It is to be returned upon request.