CBRE-3121 Presidential
1
"
4
1
"
4
1 1
1 1
4"
2 "
2 "
7"
1 1
1 1
4"
END VIEW
2 "
2 "
FACE VIEW
2 " 3"
1 1
4"
7 1
1 1
8 "
2 "
5" 3" CONNECTION PLATE NOTES: x 3 8 " PLATE x +2/( x FAB (1) PER BRACKET
3 1 4 "
GUSSET PLATE NOTES: x 1 4 " PLATE x
CONNECTION ANGLE NOTES: x L8"x8"x 1 2 "x0'-7" ANGLE x 5 8 +2/(6 x FAB (1) PER BRACKET
FAB (2) PER BRACKET
DRAWN BY
TIE-BACK CONNECTION PLATE
CG
SCALE
2"=1'-0"
o f G e o r g i a Foundation Repair & Waterproofing
675 West Paces Ferry Road Atlanta, GA
DATE
6/11/14
This drawing is the sole property of Engineered Solutions of Georgia. Reproducing or copying this drawing, in whole or in part, is prohibited without the express written permission of Engineered Solutions of Georgia. It is only to be used for the project designated herein and may not be used for any other project. It is to be returned upon request.
DRAWING NUMBER
CPT-1
Made with FlippingBook