Engineered Solutions of Georgia
Animated publication
o f G e o r g i a Foundation Repair & Waterproofing
2260 Northwest Parkway - Suite H - Marietta, GA 30067 (678) 290-1325
2 SK-3
NOTE 1
1'-0"
NOTE 2
1 SK-3
NOTE 3
EQ EQ 1'-6" EQ EQ
NOTES:
1. INDICATES LOCATION OF RESISTANCE PIERS WITH RETROFIT FOUNDATION BRACKET. EACH PIER SHALL PROVIDE 8k ALLOWABLE BEARING CAPACITY (12k ULTIMATE w/FACTOR OF SAFETY OF 1.5 FOR TEMPORARY SUPPORT). 2. INDICATES LOCATIONS OF SOIL TIE-BACK NAILS. EACH TIE-BACK SHALL PROVIDE MINIMUM ALLOWABLE PULLOUT CAPACITIES PER SKETCH 1/SK-2. LOCATIONS ARE ALSO DESIGNATED ON 1/SK-2. 3. INDICATES EXTENT OF SHOTCRETE WALL. SEE 1/SK-2 FOR A WALL ELEVATION & VERTICAL DIMENSIONS. 4. THIS SHORING PLAN ASSUMES THAT THERE EXISTS A CONCRETE STEM WALL AS SHOWN ON PLAN 2/S-2 & SECTION 4/S-5 OF THE ORIGINAL STRUCTURAL PLANS FROM PFAU ENGINEERING DATED 6/15/88. SHORING PLAN MAY HAVE TO BE ADJUSTED IF ALTERNATE CONDITIONS ARE DISCOVERED DURING EXCAVATION.
1756 Old Peachtree Road Duluth, GA 30097
ADDITION TO
1 SK-2
Old Peachtree Presbyterian Church
CLASSROM BUILDING SLAB ON GRADE
SCALE
DRAWN BY MS
3/16"=1'-0"
DATE
CG
2'-0"
8/21/2014
NOTE 4
TITLE
FOUNDATION SHORING PLAN
DRAWING NUMBER
SCALE: FOUNDATION SHORING PLAN 3/16"=1'-0"
1 SK-1
SK-1
TIE-BACK NUMBER
ALLOWABLE PULLOUT CAPACITY
REQUIRED BOND LENGTH
REQUIRED UNBONDED LENGTH 0'-0" 5'-0" 5'-0"
o f G e o r g i a Foundation Repair & Waterproofing
1 -6
1.22k
3'-10"
2260 Northwest Parkway - Suite H - Marietta, GA 30067 (678) 290-1325
7 -11
7.43k
23'-3"
12 - 18
9.45k
29'-6"
CLASSROOM BUILDING BEYOND
TIE-BACK LOCATIONS (TYP.)
10'-0"
1'-0"
6'-8"
6'-4"
6'-4"
6'-4"
6'-4"
2'-0"
1756 Old Peachtree Road Duluth, GA 30097
ADDITION TO
6
3
4
5
1
2
4'-10" 3'-10" 2'-0"
5'-0" 5'-0" 3'-0"
STAGE 1
Old Peachtree Presbyterian Church
11
7
8
9
10
EXISTING BASEMENT STEM WALL
13'-0"
STAGE 2
MS
SCALE
1/4"=1'-0"
DRAWN BY
CG
DATE
8/21/2014
18
14
15
17
12
13
16
STAGE 3
TITLE
4'-0"
4'-0"
4'-0"
4'-0"
4'-0"
4'-0"
2'-0"
WALL ELEVATION
SCALE: SHOTCRETE WALL ELEVATION 1/4"=1'-0"
1 SK-2
DRAWING NUMBER
SK-2
EXISTING EXTERIOR WALL FRAMING
o f G e o r g i a Foundation Repair & Waterproofing
CLASSROOM BUILDING
2260 Northwest Parkway - Suite H - Marietta, GA 30067 (678) 290-1325
EXTERIOR GRADE
1
2 "x8"x0'-8" BEARING PLATE w/ 1 1 4 &(17(5(' +2/(
4" MIN.
EXISTING FOOTING
NEW FOUNDATION SUPPORT BRACKET MECHANICALLY FASTENED TO EXISTING PERIMETER FOOTING. SEE 1/SK-1 FOR SPACING.
2"
TITAN 30/16 ROD (TYP.) w/ TITAN THREADS 5'-0" SECTIONS
1756 Old Peachtree Road Duluth, GA 30097
6x6-W2.9xW2.9 WELDED WIRE MESH 3,000 psi SHOTCRETE MIX
ADDITION TO
UNBONDED LENGTH SEE 1/SK-2
LOCATION AS SHOWN ON 1/SK-2
BOND LENGTH SEE 1/SK-2
Old Peachtree Presbyterian Church
RESISTANCE PIER LEAD SECTION ADVANCED TO A DEPTH TO REACH 12k ULTIMATE LOAD BEARING CAPACITY
MS
SCALE
SPHERICAL COLLAR NUT (TYP.) (PART T30-0362)
DRAWN BY
AS SHOWN
CG
DATE
8/21/2014
5,000 PSI GROUT AREA
SCALE: SECTION @ RESISTANCE PIER 3/4"=1'-0"
1 SK-3
COUPLING @ 5'-0" o/c (PART T30-0355)
NOTES: 1.
ULTIMATE LOAD FOR EACH MICRO-PILE ANCHOR IS SHOWN ON 1/SK-2 2. TOTAL BONDED LENGTH & UNBONDED LENGTH ARE SHOWN ON 1/SK-2
TITAN 30 CENTRALIZER @ 10'-0" o/c (PART P30-007) TITAN CROSS-CUT 90 BIT (PART T30-0348)
TITLE
SCALE: SECTION @ TIE-BACK SOIL NAIL 1/2"=1'-0"
2 SK-3
PIER & TIE-BACK DETAIL
DRAWING NUMBER
SK-3
Geotechnical Services Geotechnical Services
Steel Core/Auger Displacement Piles and Micro-Piles