2 SK-3
NOTE 1
1'-0"
NOTE 2
1 SK-3
NOTE 3
EQ EQ 1'-6" EQ EQ
NOTES:
1. INDICATES LOCATION OF RESISTANCE PIERS WITH RETROFIT FOUNDATION BRACKET. EACH PIER SHALL PROVIDE 8k ALLOWABLE BEARING CAPACITY (12k ULTIMATE w/FACTOR OF SAFETY OF 1.5 FOR TEMPORARY SUPPORT). 2. INDICATES LOCATIONS OF SOIL TIE-BACK NAILS. EACH TIE-BACK SHALL PROVIDE MINIMUM ALLOWABLE PULLOUT CAPACITIES PER SKETCH 1/SK-2. LOCATIONS ARE ALSO DESIGNATED ON 1/SK-2. 3. INDICATES EXTENT OF SHOTCRETE WALL. SEE 1/SK-2 FOR A WALL ELEVATION & VERTICAL DIMENSIONS. 4. THIS SHORING PLAN ASSUMES THAT THERE EXISTS A CONCRETE STEM WALL AS SHOWN ON PLAN 2/S-2 & SECTION 4/S-5 OF THE ORIGINAL STRUCTURAL PLANS FROM PFAU ENGINEERING DATED 6/15/88. SHORING PLAN MAY HAVE TO BE ADJUSTED IF ALTERNATE CONDITIONS ARE DISCOVERED DURING EXCAVATION.
1756 Old Peachtree Road Duluth, GA 30097
ADDITION TO
1 SK-2
Old Peachtree Presbyterian Church
CLASSROM BUILDING SLAB ON GRADE
SCALE
DRAWN BY MS
3/16"=1'-0"
DATE
CG
2'-0"
8/21/2014
NOTE 4
TITLE
FOUNDATION SHORING PLAN
DRAWING NUMBER
SCALE: FOUNDATION SHORING PLAN 3/16"=1'-0"
1 SK-1
SK-1