Engineered Solutions of Georgia
EXISTING EXTERIOR WALL FRAMING
o f G e o r g i a Foundation Repair & Waterproofing
CLASSROOM BUILDING
2260 Northwest Parkway - Suite H - Marietta, GA 30067 (678) 290-1325
EXTERIOR GRADE
1
2 "x8"x0'-8" BEARING PLATE w/ 1 1 4 &(17(5(' +2/(
4" MIN.
EXISTING FOOTING
NEW FOUNDATION SUPPORT BRACKET MECHANICALLY FASTENED TO EXISTING PERIMETER FOOTING. SEE 1/SK-1 FOR SPACING.
2"
TITAN 30/16 ROD (TYP.) w/ TITAN THREADS 5'-0" SECTIONS
1756 Old Peachtree Road Duluth, GA 30097
6x6-W2.9xW2.9 WELDED WIRE MESH 3,000 psi SHOTCRETE MIX
ADDITION TO
UNBONDED LENGTH SEE 1/SK-2
LOCATION AS SHOWN ON 1/SK-2
BOND LENGTH SEE 1/SK-2
Old Peachtree Presbyterian Church
RESISTANCE PIER LEAD SECTION ADVANCED TO A DEPTH TO REACH 12k ULTIMATE LOAD BEARING CAPACITY
MS
SCALE
SPHERICAL COLLAR NUT (TYP.) (PART T30-0362)
DRAWN BY
AS SHOWN
CG
DATE
8/21/2014
5,000 PSI GROUT AREA
SCALE: SECTION @ RESISTANCE PIER 3/4"=1'-0"
1 SK-3
COUPLING @ 5'-0" o/c (PART T30-0355)
NOTES: 1.
ULTIMATE LOAD FOR EACH MICRO-PILE ANCHOR IS SHOWN ON 1/SK-2 2. TOTAL BONDED LENGTH & UNBONDED LENGTH ARE SHOWN ON 1/SK-2
TITAN 30 CENTRALIZER @ 10'-0" o/c (PART P30-007) TITAN CROSS-CUT 90 BIT (PART T30-0348)
TITLE
SCALE: SECTION @ TIE-BACK SOIL NAIL 1/2"=1'-0"
2 SK-3
PIER & TIE-BACK DETAIL
DRAWING NUMBER
SK-3
Made with FlippingBook Annual report maker